How to tell if the welding machine does not shine is caused by a power supply problem?

When the laser light of the handheld welding machine does not shine, you can judge whether it is caused by a power supply problem by the following steps:

1. **Check Power Connection**:
– Confirm that the power cord of the welding machine is properly connected to the outlet and that the plug is not loose.
– Inspect the power cord for damage or breakage and replace it immediately if necessary.

2. **Check the power switch**:
– Confirm that the power switch of the welding machine is turned on and the power indicator is on.

3. **Check Voltage & Current**:
– Use a multimeter to measure the voltage of the power outlet and confirm that the voltage is within the range specified by the welding machine (usually 220V±10% AC 50/60Hz).
– Measure the voltage and current output of the power line to confirm compliance with the equipment requirements.

4. **Check the internal fuse**:
– If there is a fuse inside the welding machine, check if the fuse is blown. If the fuse is damaged, the fuse of the same size needs to be replaced.

5. **Check Controller Power**:
– Confirm that the controller’s power supply port is properly connected.
– Use a multimeter to measure the voltage of the power supply port of the controller and confirm that the power supply of the controller is normal.

6. **Check Backup Power Supply**:
– If there is a backup power supply, you can try replacing the power supply to confirm if there is no light due to power supply problems.

7. **Check System Initialization**:
– Turn off the power of the welding machine, wait a few minutes and then turn it back on to see if the system can start normally.

8. **Observe the Indicator Light and Display**:
– Check that the indicator light and display on the welding machine are displayed properly. If the indicator light doesn’t light up or the display doesn’t show, there may be a power supply problem.

If a problem with the power supply is found through the steps above, the power supply needs to be repaired or replaced. If the above steps confirm that the power supply is normal, but the welding machine still does not produce light, it may be caused by other reasons, and other parts such as control system, laser, cooling system, etc. need to be further checked.

If you need further assistance, please feel free to contact Yousheng Laser Co., Ltd.: